10KV电力变压器数据

xin****18
实名认证
店铺
DOCX
23.29KB
约7页
文档ID:153864887
10KV电力变压器数据_第1页
1/7

10KV电力变压器数据产品型号额定容量〔kVA〕额定电压联接组空载损耗〔W〕负载损耗〔W〕空载电流〔%〕阻抗电压〔%〕重量〔kg〕轨距外形尺寸〔长X宽X高〕高压〔kV〕分接范畴低压〔kV〕器身重(kg)油重(kg)总重(kg)S11-M.R-30/10306±5%0.4Y,906000.64.016585340400900x520x900S11-M.R-50/1050yn01208700.622095420950x510x980S11-M.R-63/106314010400.572601054801010x580x1000S11-M.R-80/108017512500.543001105201040x600x1020S11-M.R-100/1010020015000.483501255801150x620x1100S11-M.R-125/101256.323518000.454001356805501150x620x1100S11-M.R-160/1016028022000.424801657901200x640x1180S11-M.R-200/1020033526000.395601859301240x660x1180S11-M.-250/1025039030500.3668021011501320x700x1200S11-M.R-315/1031546536500.3380024012806601400x780x1200S11-M.R-400/1040056043000.398029015601460x820x1380S11-M.R-500/105001067051500.3120034018201520x860x142010KV级S7、S9、S11系列电力变压器技术数据容量空载损耗〔w〕负载损耗〔w〕空载电流%阻抗电压%KVAS7S9S11S7S9S11S7S9、S11S7、S9、S1130150130908006006002.82.145019017012011508708702.62.0802702501751650125012502.41.81003202902052000150015002.31.61253703402402450180018002.21.51604604002802850220022002.11.42005404803353400260026002.11.32506405603904000305030502.01.23157606704704800365036502.01.1S9与S7相比:空载损耗平均下降10.25%,年运行成本平均下降18.91%。

S11与S9相比:空载损耗平均下降30%,年运行成本平均下降11.68%S9-30〜1600/10电力变压器规格与要紧技术数据额定容量KVA联接组别电压〔KV〕损耗〔W〕阻抗电压〔%〕空载电流〔%〕重量〔kg〕外形尺寸〔长*宽*高〕高压低压空载负载器身重油重总重30Yyno100.413060042.1140702801061*729*113350101708702.0205803751105*744*1183801024012501.82801004901125*755*12831001029015001.63251105601130*815*13181601040022001.44501407601230*840*14232001048026001.35251658751357*855*14482501056030501.262519010401408*914*15083151067036501.174522012251423*1051*15334001080043001.090527514651540*1116*16085001096051001.0105030517151595*1280*166863010120062004.50.9128039521101595*1280*166880010140075000.81510455257519551325*18821000101700103000.7167552528601975*1335*19571250101950120000.6195558533302000*1340*20211600102400145000.6239067039702130*1375*2234S11-M系列全密封油浸式配电变压器是在新型S9系列产品结构设计的基础上进行开发的科技新产品。

设计的主导思想是满足产品的可靠性,提高产品的性能,依照新S9产品的实际情形,重新调整了一些损耗系数和结构,使损耗设计值更符合实测值,同时进行了优化设计,合理确定铜铁比例,使材料成本最低,结构合理S11-30〜1600/6-10电力变压器规格与要紧技术数据额定容量电压KV损耗W阻抗电压%空载电流%联接组别重量kg外形尺寸〔长*宽*高〕轨距〔mm〕高压低压空载负载器身重油重总重1020301006002.814859280980*560*1030400*400501308702.5215743761040*580*1080400*4006315010402.4249814251060*752*1100400*40080618012502.2308925071110*762*1140400*400100200150042.13491035881092*772*1170550*5501256.30.424018002.0Y,yno4171156821155*782*1214550*55016027022001.94951318071240*792*1254550*5502001033026001.85811609521400*812*1350550*55025040030501.870017811221470*818*1455550*55031548036501.880420412811448*938*1500550*55040057043001.597022515081488*848*1550550*55050068051501.4114325417601610*868*1620600*60063081062004.51.3128830620251748*1042*1635600*60098075001150103001360120001640145001.0171046327812050*1125*2170820*6600.7174853330032030*1125*2220820*6600.6205361530522220*1294*2025820*6600.6264074043272600*1326*2213820*660800100012501600变压器的连接组别介绍变压器三相绕组有星型联结、三角形联结与曲折联结等三种联结法。

在绕组联结中常用大写字母A、B、C表示高压绕组首端,用X、Y、Z表示其末端;用小写字母a、b、c表示低压绕组首端,x、y、z表示其末端,用o表示中性点新标准对星型、三角形和曲折形联结,对高压绕组分别用符号Y、D、Z表示;对中压和低压绕组分别用y、d、z表示有中性点引出时分别用YN、ZN和yn、zn表示自藕变压器有公共部分的两绕组中额定电压低的一个用符号a表示变压器按高压、中压和低压绕组联结的顺序组合起来确实是绕组的联结组例如:高压为Y,低压为yn联结,那么绕组联结组为Yyn加上时钟法表示高低压侧相量关系确实是联结组别常用的三种联结组别有不同的特点:1 Y联结:绕组电流等于线电流,绕组电压等于线电压的1/V3,且能够做成分级绝缘;另外,中性点引出接地,也能够用来实现四线制供电这种联结的要紧缺点是没有三次谐波电流的循环回路2 D联结:D联结的特点与Y联结的特点正好相反3 Z联结:Z联结具有Y联结的优点,匝数要比Y形联结多15.5%成本较大据GB/T6451-1999«三相油浸式电力变压器技术参数和要求》和GB/T10228-1997«干式电力变压器技术参数和要求》规定,配电变压器可采纳Dyn11联结。

而我国新颁布的国家规范«民用建筑电气设计规范»、«工业与民用供配电系统设计规范》、《10KV及以下变电所设计规范》等举荐采纳Dyn11联结变压器用作配电变压器现在国际上大多数国家的配电变压器均采纳Dyn11联结,要紧是由于采纳Dyn11联结较之采纳YynO联结有优点:3.1D联结对抑制高次谐波的恶劣阻碍有专门大作用3.1.1在D联结绕组中的三次谐波环流能够在变压器中产生三次谐波磁动势,它与低压绕组的三次谐波磁动势平稳抵消;3.1.2高压相绕组的三次谐波电动势在D联结回路中环流,三次谐波电流可在D联结的一次绕组内形成环流,使之不致注入公共的高压电网中去3.2Dynll联结变压器的零序阻抗比YynO联结变压器小得多,有利于低压单相接地短路故障的切除3.3Dynll联结变压器承诺中性线电流达到相电流的75%以上因此,其承担不平稳负载的能力远比YynO联结变压器大3.4当高压侧一相熔丝熔断时,Dynll联结变压器另二相负载仍可运行,而YynO却不行因此,在变压器联结组别选择中,选择Dynll联结变压器专门有必要由于YynO联结变压器高压绕组的绝缘强度要求较之Dynll联结变压器稍低,因此,不宜将YynO联结变压器改为Dynll联结。